POYESHYAR Co. Ltd.

Inspection Equipment Supplier

 

Gamma Projectors

 
     
 
 
     

Gammamat Gamma Radiography Industrial Testing Systems


gammamat test equipment has been setting the highest standards for industrial gamma radiography for over fifty years. Today, the name gammamat is recognized as the symbol of market leadership. gammamat test equipment and systems provide unparalleled safety and reliability. Compact and lightweight, it is renowned for its state-of-the-art technology, innovative design, and unrivalled reliability.

 

 

Model

Max loading

Total weight  

Catalogue

gammamat TI compact, lightweight Ir-192 gamma ray projector

TI

1,50 TBq (40 Ci) Ir-192

13,0 kg (28.6 lb)

TI-F

3,70 TBq (100 Ci) Ir-192

16,0 kg (35.2 lb)

TI-FF

7,50 TBq (200 Ci) Ir-192

18,5 kg (40.7 lb)

The gammamat TI was the first gammamat unit to be recognized as the standard for technology, safety, reliability and ease-of-use in the field of gamma radiography. The wide range of applications includes the maintenance of aircraft as well as examination of power and chemical plants.
These devices incorporate a straight source channel with an eccentric shutter.

 

Model

Max loading

Total weight  

Catalogue

gammamat TSI/1industry standard Ir-192 gamma ray projector

TSI 3/1

3,0 TBq (80 Ci) Ir-192

20,0 kg (44.0 lb)

TSI 5/1

5,0 TBq (135 Ci) Ir-192

22,0 kg (48.4 lb)

The gammamat TSI/1 is the latest model in the gammamat Series. It is the product of many years of evolution of gamma radiography devices for the universal application of iridium 192 sources. It incorporates a straight source channel, and a completely new, patented radiation labyrinth made of tungsten. The gammamat TSI uses no uranium moving parts and it is smaller and lighter than the conventional S-channel devices.

 

Model

Max loading

Total weight  

Catalogue

gammamat TK industry standard Co-60 gamma ray projector

 

TK 30

1,10 TBq (30 Ci) Co-60

81,7 kg (179.7 lb)

TK 100

3,70 TBq (100 Ci) Co-60

106,4 kg (234.1 lb)

TK 1000

23,00 TBq (600 Ci) Co-60

210,0 kg (462.0 lb)

The gammamat TK Series’ useful operating range for steel is 30 to 250 mm. For concrete, good results are obtained up to a thickness of approximately 1 meter. This series can be used with electromechanical remote controls and an automatic shutter. They can be interlocked to door switches to increase the ease-of-operation. They offer the highest standards of safety.

 
 

Model

Max loading

Total weight  

Catalogue

gammamat SE highly portable Se-75 gamma ray projector

 

SE

3,0 TBq (80 Ci) Se-75

7,20 kg (15.8 lb)

The gammamat SE is a gamma ray projector with unparalleled handiness and extremely low weight. The use of Selenium-75 radiation source yields improved image quality. The longer half-life and simplified radiation protection result in substantial cost savings. Compared to cameras that use Ir-192 sources, it can be safely used in smaller controlled test areas.
 

gammamat Accessories

 

Tungsten collimators

Source guide tubes

Centring and positioning devices

Manual remote controls

Tungsten collimators
The large offering of tungsten collimators, designed for differing source types and shielding requirements can be combined to achieve various beam configurations.

Source guide tubes

The gammamat range of rigid and flexible source guide tubes in various lengths allows optimum positioning of the source during radiographic operations.

Centering and positioning devices
A wide range of centering and positioning devices for source guide tubes, collimators, and gammamat exposure devices are available. These include magnetic, strap and chain supports, pipe tongs for elliptical exposures, and pipe centering devices for both small and large diameter pipes.

Manual Remote Controls
Remote controls are an essential safety component of the gammamat systems. They allow the operation of the radioactive source form a safe distance.
All GammaMat remote controls are manufactured to tolerances that ensure that the controls are properly connected to the camera and source holder before the source can be extended.

 

gammatel ES automatic drive system for gammamat equipment

 

The gammatel ES is an electrically-powered automatic drive system for gammamat devices. Contributing to operator safety and convenience, the gammatel ES consists of a drive unit with a small, easily removable control panel. The gammatel ES is principally designed for stationary applications, but it can also be used in mobile field settings where safety hazards require the operator to maintain a distance from the drive unit.

User friendly remote control and monitoring
The gammatel ES allows gammamat devices with automatic shutters to be operated and closed via remote control. All inputs regarding the start of the irradiation, exposure time, and exposure pre-warning time are done via the unit’s twelve input keys, and viewed on the LED display. The starting time and duration of exposure can be precisely preset. Entries are prompt and menu-driven. All entries, as well as the elapsed exposure time and source travel distance, can be checked on the display at any time.

Operating distance
The operating control and drive unit are connected by a cable 10 meters (11 yd) long.

Safety features
Safety interlock circuitry allows connection of door contact switches to prevent exposure of the source while the exposure room doors are open. The circuitry also automatically retracts the source in the event that the door or other circuit switches are opened during exposure.
Emergency switches that trigger an immediate retraction of the source are located at both the control panel and drive unit. The program can then be resumed later from the interruption point. Batteries allow the source to be retracted in case of a power failure. Manual retraction of the source is also possible.

 
     

 

[ Home ] [ Products ] [ News ] [ Links ] [ Contact Us ] [ Site Map ] [ Farsi ]

No 15 , Golshahr Blvd. Africa St. Tehran, Iran Tel: +98 21 2204 8765 Fax: +98 21 2205 6482